FIBERFUTURE factory-priced mini 1x16 PLC splitter is compact and cost-effective, designed for efficient signal distribution in fiber optic networks without connectors, making it ideal for custom installations requiring flexibility and space-saving solutions.
| Model | Output Tube Diameter | Inlet/Outlet Fiber Length | Pipe Sizes |
| 1*2 ABS Box Splitter | 0.25mm/0.9mm | 1m | 4mm*7mm*50mm |
| 1*4 ABS Box Splitter | 0.25mm/0.9mm | 1m | 4mm*7mm*50mm |
| 1*8 ABS Box Splitter | 0.25mm/0.9mm | 1m | 4mm*7mm*60mm |
| 2*16 ABS Box Splitter | 0.25mm/0.9mm | 1m | 4mm*12mm*60mm |
| 2*32 ABS Box Splitter | 0.25mm/0.9mm | 1m | 6mm*20mm*80mm |
| 2*64 ABS Box Splitter | 0.25mm/0.9mm | 1m | 6mm*40mm*100mm |
| Projects | Parameter |
| Operating Temperature | -25°C ~ +40°C |
| Storage Temperature | -25°C ~ +55°C |
| Relative Humidity | ≤85% (+30°C) |
| Air Pressure | 70 KPa ~ 106 KPa |
| Type | 1x2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 | |
| Operating Wavelength (nm) | 1260-1650 | ||||||
| Insertion Loss (dB) | Max | 3.8 | 7.2 | 10.2 | 13.5 | 16.5 | 20.5 |
| Loss uniformity (dB) | Max | 0.5 | 0.6 | 0.8 | 1.0 | 1.5 | 2.0 |
| Return Loss (dB) | ≥50 | ||||||
| Polarization Dependent Loss (dB) | Max | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 |
| Directivity (dB) | ≥55 | ||||||
| Fiber Type | SMF-28E or Customer Designation | ||||||
| Wavelength Dependent Loss (dB) | Max | 0.6 | 0.6 | 0.6 | 0.8 | 0.8 | 0.8 |
| Temperature Correlation Loss -40~85℃ (dB) | Typical Value | 0.2 | 0.2 | 0.3 | 0.4 | 0.4 | 0.4 |
| Max | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
| Working Temperature (℃) | -40~85℃ | ||||||
| Storage Temperature (℃) | |||||||
| Type | 2x2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | |
| Operating Wavelength (nm) | 1260-1650 | ||||||
| Insertion Loss (dB) | Max | 4.0 | 7.4 | 10.5 | 13.9 | 17.0 | 20.5 |
| Loss uniformity (dB) | Max | 0.5 | 0.6 | 0.8 | 1.0 | 1.5 | 2.0 |
| Return Loss (dB) | ≥50 | ||||||
| Polarization Dependent Loss (dB) | Max | 0.2 | 0.2 | 0.3 | 0.3 | 0.3 | 0.4 |
| Directivity (dB) | ≥55 | ||||||
| Fiber Type | SMF-28E or Customer Designation | ||||||
| Wavelength Dependent Loss (dB) | Max | 0.6 | 0.6 | 0.6 | 0.8 | 0.8 | 0.8 |
| Temperature Correlation Loss -40~85℃ (dB) | Typical Value | 0.2 | 0.2 | 0.3 | 0.4 | 0.4 | 0.4 |
| Max | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | |
| Working Temperature (℃) | -40~85℃ | ||||||
| Storage Temperature (℃) | |||||||
Save money - with manufacturer direct pricing
Save time - with experienced team to get project done
Lead the industry - with the most cutting-edge products